Blink 120kw vs ChargePoint 125kw DC Charger are two high-performance electric vehicle charging solutions designed for rapid and efficient energy delivery. Blink 120kw vs ChargePoint 125kw offer flexible connectivity options, advanced safety features, and compatibility with multiple connector types, catering to the growing demand for fast EV charging infrastructure.

FeatureBlink 120kW DC FAST ChargerChargePoint Express 125kW DC Charger
Input Voltage / Frequency480VAC (3P+N+PE) / 60Hz480VAC / 60Hz
Breaker Rating160A200A (or larger)
Rated Power132.9kVANot specified
Output Voltage150-1000VDCNot specified
Output CurrentUp to 400ANot specified
Maximum Power Output120kW125kW (when paired) / Up to 62.5kW per port
Connector OptionsCCS1, CHAdeMO, NACSCCS, CHAdeMO, NACS
Cable SpecificationsCCS: Up to 300A (Nominal), 350A (Peak); CHAdeMO: Up to 125A; NACS: Up to 400A (All Air Cooled)Not specified
Cycle Mode / Parallel Mode1 x 120kW (Max 400A) / 2 x 60kW (Max 400A)Not specified
Efficiency≥ 94% at nominal output powerNot specified
Power Factor> 0.98 @ full loadNot specified
Operating Temperature Range-4°F to 131°F (-20°C to 55°C)-40°F to 122°F (-40°C to 50°C)
Altitude< 6600 ft (2000m)Not specified
Humidity≤ 95% RH (Working) / ≤ 99% RH (Storage, Non-condensing)Not specified
Weight816 lbs (370 kg)Not specified
Dimensions39.96’’ x 29.52’’ x 73.42’’7’4″ x 2’5″ x 1’5″ (2241 x 730 x 441 mm)
Display10’’ LCD Touch Screen10 in full-color touch-sensitive screen with multi-language support
Access Control / Payment OptionsRFID: ISO/IEC 14443A/B, Credit Card ReaderRFID, NFC (Tap to Charge), Remote App, Contactless Credit Card, EMV Chip Option
Ingress ProtectionNEMA 3S (IP54), IK 10Type 3R, IP54, IK10
Cooling SystemAir CooledNot specified
Charging ProtocolMode 4 – IEC-61851, ISO-15118, DIN 70121; CHAdeMO 0.9, 1.0Not specified
Connector Cable Length16 ft (5 m) for all connectors14 ft (4.27 m)
Cable ManagementIncluded for all connectorsNot specified
Network/Communication ProtocolOCPP 1.6J, Ethernet, WiFi, 4GOCPP 1.6, Cellular 4G LTE, Wi-Fi LAN
Insulation (Input-Output)> 2.5kVNot specified
Electrical SafetyGFCI RCD 20mA Type A, Surge Protection 20kA, Over Voltage, Under Voltage, Over Current, Missing Ground, Output Short Circuit Protection, Temperature Sensors @ Charge Coupler and Power Electronics, Emergency Stop ButtonUL 2202, UL 2231-1, UL 2231-2, CSA 107.1, CE marking: IEC 62196, IEC 61851, FCC part 15 Class A, EU: EN55011, EN55022, IEC61000-4
Regulatory ComplianceUL 2202, UL 2231-2, EMC: EN 61000-6-1:2007, EN 61000-6-3:2007/A1:2011/AC:2012UL and cUL listed, California Type Evaluation Program (CTEP), National Type Evaluation Program (NTEP), Buy America FTA
MeteringDC kWh meter per connectorNot specified
Mounting OptionsNot specifiedGround, Wall
Number of PortsNot specifiedSingle, Paired